Alarm Settings
Parameter
Description
Programming
Options
Parameter
Description
Programming
Options
Parameter
Description
Programming
Options
4-26
Sync Loss Relay
Determines whether the system closes the alarm relay on the ISDN
MDF card in the event of sync loss alarms.
The alarm relay can be connected to an external alarm device such
as a buzzer. The external alarm device must be purchased sepa-
rately; it is not provided with the DBS ISDN.
Sync-loss alarms result from clocking errors.
Master cabinet: FF1 9# 4# 4# 4# 3# (0-1)#
Slave cabinet: FF1 9# 4# 5# 4# 3# (0-1)#
0=Off (Alarm relay does not close.)
1=On (Alarm relay closes.)
Frame Loss Relay
Determines whether the system closes the alarm relay on the ISDN
MDF card in the event of frame loss alarms.
The alarm relay can be connected to an external alarm device such
as a buzzer. The external alarm device must be purchased sepa-
rately; it is not provided with the DBS ISDN.
Master cabinet: FF1 9# 4# 4# 4# 4# (0-1)#
Slave cabinet: FF1 9# 4# 5# 4# 4# (0-1)#
0=Off (Alarm relay does not close.)
1=On (Alarm relay closes.)
AIS Relay
Determines whether the system closes the alarm relay on the ISDN
MDF card in the event of alarm indication signals.
An alarm indication signal is comprised of all 1's and is unframed.
The alarm relay can be connected to an external alarm device such
as a buzzer. The external alarm device must be purchased sepa-
rately; it is not provided with the DBS ISDN.
Master cabinet: FF1 9# 4# 4# 4# 5# (0-1)#
Slave cabinet: FF1 9# 4# 5# 4# 5# (0-1)#
0=Off (Alarm relay does not close.)
1=On (Alarm relay closes.)