Installation Procedures

Installation Procedures

The following procedures provide step-by-step instructions for installing the
CSU and the ISDN Interface. The ISDN procedure that you should use
depends on the type of system you have and the number of ISDNs you are
installing.
If you're installing ...
A ISDN in a single cabinet
One ISDN in a double cabinet, with the
ISDN located in the master
One ISDN in a double cabinets, with the
ISDN located in the slave
ISDNs in both the master and slave

Installing the CSU

The following instructions explain how to install the CSU. See "CSU
Equipment" on page 1-9 for specifications on CSUs and CSU cabling.
Note: The CSU can be powered locally or through the CO line. Also, a
locally powered CSU should be connected to an Uninterruptible Power
Supply (UPS) to provide battery backup in case of AC power failures.
1. Connect the equipment cable from the DBS MDF card to the equipment
2-12
side of the CSU, as shown in Figure 2-1.
DBS-EX23-530
Use this procedure...
"Installing an ISDN in a Single Cabinet" (page 2-
14)
"Installing an ISDN in a Single Cabinet" (page 2-
14)
"Installing an ISDN in a Double Cabinet with the
ISDN in the Slave" (page 2-21)
"Installing an ISDN in a Double Cabinet with
ISDNs in the Master and Slave" (page 2-23)
Installation
Revised April 2000