Programming Reference
Parameter
Description
Programming
Options
Parameter
Description
Programming
Options
Revised April 2000
Slip Counter
Determines how many slips occur before a Slip FF key is lit.
The FF key lights when the counter exceeds the specified number
within a 24-hour period.
This parameter also determines the number of slips that can occur
before the system switches to the next clock source. When the sys-
tem switches to the next clock source, the slip error counter for the
first clock source is reset.
Slips are losses of data bits due to framing errors.
(See page 4-35 for instructions on programming FF alarm keys.)
Master cabinet: FF1 9# 4# 4# 3# 2# (0-9000)#
Slave cabinet: FF1 9# 4# 5# 3# 2# (0-9000)#
0-9000/24 hours (9000)
Red Alarm Counter
Determines how many red alarms occur before a Red Alarm FF
key is lit.
The FF key lights when the counter exceeds the specified number
within a 24-hour period.
(See page 4-35 for instructions on programming FF alarm keys.)
Master cabinet: FF1 9# 4# 4# 3# 3# (0-9000)#
Slave cabinet: FF1 9# 4# 5# 3# 3# (0-9000)#
/
0-9000
24 hours (9000)
DBS-EX23-530
Alarm Settings
4-23