17

Working with alarms

17.1 Working with color alarms

17.1.1 General

A color alarm applies a contrasting color to all pixels with a temperature above, below, or
between one or more set temperature levels.
Using a color alarm is a good method to easily discover anomalies in an infrared image.

17.1.2 Procedure

Follow this procedure:
1. Push the navigation pad to display the menu system.
2. Use the navigation pad to go to Color.
3. Push the navigation pad. This displays a color toolbar.
4. On the toolbar, select one of the following and push the navigation pad:
• Above alarm: A color alarm that colorizes all parts of the image that are above a
set temperature level. Use the navigation pad to change the temperature.
• Below alarm: A color alarm that colorizes all parts of the image that are below a
set temperature level. Use the navigation pad to change the temperature.
• Interval alarm: An interval color alarm that colorizes all parts of the image that fall
between two set temperature levels. Use the navigation pad to change the temper-
ature levels.

17.2 Working with insulation alarms

17.2.1 General
The Insulation alarm can detect areas where there may be an insulation deficiency in a
building. It will trigger when the insulation level (termed the thermal index in the camera
menu) falls below or above a preset value of the energy leakage through a wall (depend-
ing on the climate conditions).
Different building codes recommend different values for the insulation level, but typical
values are 60–80% for new buildings. Refer to your national building code for
recommendations.
17.2.2 Procedure
Follow this procedure:
1. Push the navigation pad to display the menu system.
2. Use the navigation pad to go to Color.
3. Push the navigation pad.