Flir E60 - FLIR Exx series User Manual

Hide thumbs Also See for Exx series:
Table of Contents

Advertisement

23
Technical data

23.13 FLIR E60

P/N: 64502-1202
Rev.: 35207
General description
The FLIR Exx series cameras are compact and rugged infrared cameras that can be used in harsh envi-
ronments while still providing you with the latest technology such as a modern touch screen. A FLIR
Exx series camera is the perfect choice when you are looking for a robust but feature-rich camera at an
affordable price.
Benefits:
Robust and sophisticated: The FLIR Exx series cameras have a robust and light-weight design and
can withstand a 2 m drop. Large buttons combined with a modern touch screen and extensive
measuring capabilities, they are the right choice for demanding inspections in the field.
Best value for money: The FLIR Exx series cameras combine good performance (up to 320 × 240
pixels), a user-friendly interface, and a rugged point-and-shoot design with an affordable price.
Imaging and optical data
IR resolution
Thermal sensitivity/NETD
Field of view (FOV)
Minimum focus distance
Focal length
Spatial resolution (IFOV)
F-number
Image frequency
Focus
Digital zoom
Panning
Detector data
Detector type
Spectral range
Image presentation
Display
Image adjustment
Image presentation modes
Image modes
Picture in Picture
Measurement
Object temperature range
Accuracy
Measurement analysis
Spotmeter
Area
Automatic hot/cold detection
#T559845; r. AJ/37554/37554; en-US
320 × 240 pixels
< 0.05°C @ +30°C (+86°F) / 50 mK
25° × 19°
0.4 m (1.31 ft.)
18 mm (0.7 in.)
1.36 mrad
1.3
60 Hz
Manual
2× and 4×
Panning over zoomed-in images
Focal plane array (FPA), uncooled
microbolometer
7.5–13 µm
Touch screen, 3.5 in. LCD, 320 × 240 pixels
Auto or manual
IR image, visual image, MSX, picture in picture,
thumbnail gallery
Scalable IR area on visual image
–20°C to +120°C (–4°F to +248°F)
0°C to +650°C (+32°F to +1202°F)
±2°C (±3.6°F) or ±2% of reading, for ambient tem-
perature 10°C to 35°C (+50°F to 95°F)
3
3 boxes with max./min./average
Auto hot or cold spotmeter markers within area
98

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

E40E50E60

Table of Contents