Lombardini Engine Troubleshooting
5.8
Checking Voltage to Glow Plugs (Lombardini 1003 engines)
See Graphic: wc_gr003229
5.8.1
5.8.2
a
wc_tx000364gb.fm
To check the voltage to the glow plugs, carry out the following
procedure:
Disconnect the B (black) wire (a), place the keyswitch in the START
position, and measure the voltage between the black wire and ground.
There should be 12V (battery voltage approximately 12) measured.
•
If 12V is measured, check the function of the glow plug.
•
If 12V is not measured, continue.
Disconnect the B (black) wire (b) and measure the voltage between it
and ground. There should be 12V (battery voltage approximately 12)
measured.
•
If 12V is measured, clean the connection points of the wires.
Reconnect the wires and check the function of the glow plug.
•
If 12V is not measured, check the glow plug relay.
b
70
LTC Repair
wc_gr003229