Air Cleaner - WACKER Group LTC 4 Repair Manual

Light tower
Table of Contents

Advertisement

LTC Repair
4.7

Air Cleaner

See Graphic: wc_gr002478
WARNING
4.7.1
4.7.2
4.7.3
4.7.4
wc_tx000427gb.fm
DO NOT attempt to clean or service the machine while it is running.
CAUTION: DO NOT operate the engine without an air cleaner.
Note: Caterpillar engines are equipped with a filter indicator (a), which
indicates when a filter change is required. Replace the main paper filter
element when the yellow plunger of the indicator appears in or near the
red line. Push and hold in the yellow rubber button on top of the
indicator to reset it after replacing the main paper filter element.
Lombardini engines include a light (b) on the engine control panel
which, when lit, indicates when a filter change is required.
Open air the cleaner and remove the element.
Inspect the air filter; replace it as needed.
To clean the filter, lightly tap it on a hard surface to eliminate all excess
dirt. Do not blow the paper filter element with compressed air to clean.
Clean the filter cover and support carefully.
Reassemble the filtering element and the air cleaner.
47
Maintenance

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents