7.27 Replacing Generator Capacitor(s)

See Graphic: wc_gr002460
7.27.1 Note the connection points of the #60 (#50 on 50Hz machines) and #0
7.27.2 Remove the jumper wire (c) connecting the two capacitors.
7.27.3 Cut the wire ties (d) and remove the capacitor(s).
7.27.4 Insert the capacitors (b) and secure with new wire ties (d).
7.27.5 Attach the #60 (#50 on 50Hz machines) and #0 wires to the
7.27.6 Attach the jumper wire (c).
wc_tx000429gb.fm
Carry out this procedure with the engine shut down.
Removal:
wires and remove the wires (a) from the capacitor (b).
Installation:
appropriate terminals on the capacitor.