4.2
Periodic Maintenance Schedule—CAT
Visual walkaround inspection.
Check for fluid leaks.
Check engine oil and coolant level.
Check fuel level.
Replace air filter if indicator light is on.**
Change engine oil and filter.*
Check level of battery electrolyte.
Check condition and tension on fan belt.
Check condition of radiator hoses. Replace
radiator hoses and clamps.
Flush radiator.
Replace fuel filter.
Check valve clearance.
Remove sediment in fuel tank.
Change radiator coolant.
Replace battery.
Replace fuel pipes and clamps.
* Change engine oil and filter after first 50 hours of operation.
** Replace air filter after air filter restriction switch indication or one year.
4.3

Daily Inspection

4.3.1
4.3.2
4.3.3
4.3.4
wc_tx000427gb.fm
Check for fluid leaks. Check fluid levels.
Inspect condition of electrical cords. Do not use light tower if insulation
is cut or worn through.
Check that winch cables are in good condition. Do not use a cable that
is kinked or starting to unravel.
Check that the vertical mast locking pin and its spring are secured,
aligned, and operating properly.