WACKER Group LTC 4 Repair Manual page 125

Light tower
Table of Contents

Advertisement

LTC Repair
Electrical Troubleshooting
B
G
R
W
T5
T1
T1 to T2: 0.36 +0.5/-0.0
T4 to T5: 0.36 +0.5/-0.0
#0 to #60: 1.7 +0.5/-0.0
T2
T4
T1 to ground: OL
T5 to ground: OL
1000
F
T6
T3
V
200
20
2
200m
#60 to ground: OL
#60 to T1: OL
A
#60 to T5: OL
V-
COM
60
0
wc_gr003097