Gp 1 Machine Specifications - Xerox FaxCentre F116 Service Manual

Hide thumbs Also See for FaxCentre F116:
Table of Contents

Advertisement

GP 1 Machine Specifications

Operating Specifications
Environment
• Operating:
- The machine should not be exposed to
direct sunlight.
- Supply: 110-127 V - 50/60 Hz.
- Power consumption, standby: ≤ 15 W.
- Power consumption, printing: 850 W
max.
- Temperature: 40 to 95 F (10 to 35 °C).
- Temperature changes: ≤ 10 °C/hour.
- Humidity: 20 % to 80 % (RH non-con-
densing).
- Humidity changes: ≤ 20 %/hour.
- Altitude: 0 to 8,200 Feet (0 to 2,500
meters) (above sea level).
- Ambient light: ≤ 3000 lux.
General technical characteristics
Equipment
Dimensions (width x depth x height, without trays)
Weight
Consumables
Reference Paper (RP)
Type
FaxCentre F116/F116L
Storage
machine:
- Temperature: 32 to 104 F (0 to 40 °C).
- Temperature changes: ≤ 10 °C/hour.
- Humidity: 20 % to 80 % (RH non-con-
densing).
- Humidity changes: ≤ 20 %/hour.
- Altitude: from 0 to 8,200 Feet (0 to 2,500
meters) (above sea level).
consumables (drum and toner cartridge):
- Normal temperature: 32 to 95 F (0 to 35
°C).
- Extreme temperatures: - 40 to 32 F (- 10
to 0 °C) and 95 to 104 F (35 to 40 °C)
(less than 10 % of the storage time).
- Humidity: 20 % to 90 % (RH non-con-
densing).
Maximum storage time: 18 months
15.30 x 18.10 x 15.35 inch
Letter: 20 lbs/m
9/04
General Procedures/Information
F116
389 x 460 x 390 mm
24.25 lbs - 11 kg
2
- 75 g/m
2
6-3

Advertisement