7. IO-Link Connection Procedure

This section describes the procedures for connecting Photoelectric Sensor to IO-Link Master
Unit via IO-Link and for connecting PLC to Slave Terminal configured of IO-Link Master Unit
on the EtherNet/IP network. The explanations of procedures for setting up PLC and Slave
Terminal given in this document are based on the factory default settings.
For the initialization, refer to Section 8. Initialization Method.

7.1. Work Flow

Take the following steps to connect Photoelectric Sensor to IO-Link Master Unit via IO-Link
and to connect PLC to Slave Terminal configured of IO-Link Master Unit on the EtherNet/IP
network.
7.2. Slave Terminal Setup
7.2.1. Hardware Settings
7.2.2. Starting Sysmac Studio and
Connecting Online with Slave
Terminal
7.2.3. Setting the Slave Terminal
Configuration Information
7.2.4. IO-Link Master Unit Setup
7.2.5. I/O Allocation Settings
7.2.6. Transferring the Setting Data
7.3. PLC Setup
7.3.1. Hardware Settings
7.3.2. Starting CX-Programmer and
Connecting Online with PLC
7.3.3. Creating the I/O Table and
Setting the IP Address
7.IO-Link Connection Procedure
Set up Slave Terminal.
Configure Slave Terminal, set hardware switches,
and connect Photoelectric Sensor.
Start Sysmac Studio and connect online with Slave
Terminal.
Set the Slave Terminal configuration information.
Set the parameters for IO-Link Master Unit.
Set the I/O allocations for IO-Link Master Unit.
Transfer the setting data of Slave Terminal to
EtherNet/IP Coupler Unit.
Set up PLC.
Set the hardware switches on EtherNet/IP Unit and
wire the network.
Start CX-Programmer and connect online with
PLC.
Create the I/O table and set the IP address of PLC.