Advertisement

5
Check the LED indicator on
Photoelectric Sensor.
The LED indicator in normal status
is as follows:
Stability indicator / IO-Link
Communication indicator:
6
The normal operation of tag data
links is confirmed through the status
information in the Monitor Device
Dialog Box of Network Configurator.
Right-click the device icon of node 1
in the Network Configuration Pane
and select Monitor.
7
The dialog box on the right displays
the Status 1 Tab Page in the Monitor
Device Dialog Box.
When the same check boxes are
selected as shown on the right, the
tag data links are normally in
operation.
Click Close.
<Top view of Photoelectric Sensor>
Green flashing
(1sec cycle)
7.IO-Link Connection Procedure
Stability indicator/
IO-Link Communication indicator
Number: Node number
Blue: Connection normal
49