3.3

Environmental Specifications

Altitude: 2000 meters
Operating Temperature:
-14° to 122°F (-25 to 50°C), 80% RH, non-condensing
NOTE: If the meter is to be used below 32°F (0°C), we suggest
that the battery be replaced to ensure proper results.
Storage Temperature:
-14° to 140°F (-25° to 60°C) < 80% RH
3.4

Safety Specifications

EN 61010-1 Ed.2001
EN 61010-2-032 Ed.2002
600V CAT IV, 1000V CAT III
Pollution Degree 2
Electromagnetic Compatibility (per NF EN 61326)
Compliant with electromagnetic compatibility standard
NF EN 61326-1 (07/97) + A1 (10/98) + A2 ( 09/2001)
- Radiated and conducted emission (NF EN 55022)
- Radiated Immunity, criterion B (NF EN 61000-4-3)
- Conducted Immunity, criterion A (NF EN 61000-4-6)
- Electrostatic discharges, criterion A (NF EN 61000-4-2)
- Transients, criterion B (NF EN 61000-4-4)
- Shock waves, criterion A (NF EN 61000-4-5)
Note: Certain high power radio-electric frequencies are,
under certain conditions, capable of interfering with the
metrological integrity of the meter.
*Specifications are subject to change without notice