Si-86.book Page 20 Friday, June 23, 2000 10:26 AM
General Functionality
1.8

Fan Speed Control for Outdoor Units

Control
The following drawing explains the fan speed control:
Fan off delay
When the compressor turns off and T
speed for
20
ON
OFF
A
˚C
[outdoor ambient]
E
seconds.
A
(˚C)
H type
28
J type
33
Caution
J type operates the outdoor unit fans in the cooling mode even at the condition that a compressor is
not operated. (In case of existing model H series, the outdoor unit fans stops at the condition that a
compressor is not operated.)
For ambient temperature
between
B
˚C
outdoor heat exchanger temperature
D
>
˚C, the outdoor fan stays running at the same
B
(˚C)
C
(˚C)
D
34
0 - 18
10
39
0 - 9
10
SIE-86
C
˚C.
(RL014)
(˚C)
E
(sec)
30
60
Main Function