General Functionality
1.5

Forced Operation Mode

1.5.1
H type
Forced mode
The following table explains the different forced operation modes, forced cooling and forced heating:
Conditions
Start
Adjustment
(H type)
Reset
(H type)
The protective functions overrule the forced mode. (H type only)
1.5.2
J type
Forced mode
Conditions
Start
Adjustment
Reset
A way to enter the test operation mode by a remote controller.
1. Set on the desirous mode and push ON/OFF button. (operation ON)
2. Two buttons; Center of temperature set buttons "
3. Moreover, push "MODE" button twice. (If the liquid crystal display becomes "
16
Item
Forced cooling
not in the 3-minute stand-by mode
normal operation mode
outdoor unit off
no malfunction in the outdoor unit
forced mode: cooling mode.
Press the forced operation switch SW1 to
start the following items:
command frequency: 66 Hz
timer: 60-minute
fan speed: H
swing flap: preservation of last setting
indoor adjustment: send forced mode to
unit.
Press the forced operation switch again or after
60 minutes.
Item
Forced cooling
not in the 3-minute stand-by mode
normal operation mode
outdoor unit off
no malfunction in the outdoor unit
forced mode: cooling mode.
1. Keep pushing the operation switch of the
indoor unit for 5 to 10 seconds.
2. Change the remote controller setting to a
cooling test operation.
( Regarding a way to enter the test
operation, refer to the note in a margin
below)
Possible to enter the forced cooling mode by
either way of 1. or 2..
Fix operation frequency to 66 Hz.
Operation-on timer :15 min.
Indoor unit's fan : H tap.
Swing flap: the latest set position.
1. Push the operation switch of the indoor unit
in an usual way.
2. Push the stop button on a remote controller.
3. Operation-on timer : 15 min. overtime.
simultaneously. (then a left figure of the liquid crystal temperature's display number starts to blink.)
mode will startup under the mode displayed in a liquid crystal. )
Forced heating
not in the 3-minute stand-by mode
normal operation mode
outdoor unit off
no malfunction in the outdoor unit
forced mode: heating mode.
Press the forced operation switch SW1
while short circuiting SW2 to start the
following items:
command frequency: 66 Hz
timer: 60-minute
fan speed: H
swing flap: preservation of last setting
indoor adjustment: send forced mode to
unit.
Press the forced operation switch again or after
60 minutes.
Forced heating
not in the 3-minute stand-by mode
normal operation mode
outdoor unit off
no malfunction in the outdoor unit
forced mode: heating mode.
With a change of the remote controller setting
to a heating test operation, the unit enters the
forced heating mode.
(Regarding a way to enter the test operation
mode, refer to the note in a margin below)
Fix operation frequency to 66 Hz.
Operation-on timer :15 min.
Indoor unit's fan : H tap.
Swing flap: the latest set position.
1. Push the operation switch of the indoor unit
in an usual way.
2. Push the stop button on a remote controller.
3. Operation-on timer : 15 min. overtime.
", and " Mode" button, should be pushed
TEMP
", the test operation
SIE-86
Main Function