Precautions; Troubleshooting Hints - APRILIA SR MAX 125 ie Service Station Manual

Table of Contents

Advertisement

SR MAX 125 ie

Precautions

1 A MIU failure is more likely to be due to the connections than to the components.
Before troubleshooting the MIU system, carry out the following checks:
A: Electrical power supply
a. Battery voltage
b. Blown fuse
c. Remote controls
d. Connectors
B: Chassis ground
C: Fuel system
a. Broken fuel pump
b. Dirty fuel filter
D: Ignition system
a. Faulty spark plug
b. Broken coil
c. Broken shielded cap
E: Intake circuit
a. Dirty air filter
b. Dirty by-pass circuit
c. Faulty Stepper motor
F: Other
a. Incorrect distribution timing
b. Wrong idle mixture
c.Incorrect reset of the throttle valve position sensor
2 MIU system faults may be caused by loose connectors. Make sure that all connections have been
correctly made.
Check the connections as follows:
A check that the terminals are not bent.
B check that the connectors have been properly connected.
C check whether the malfunction can be fixed by shaking the connector slightly.
3 Check the entire system before replacing the MIUIf the fault is fixed by replacing the MIU control unit,
install the original control unit again and check if the fault occurs again.
4 Use a multimeter with an internal resistance of more than 10K Ohm /V when troubleshooting. Instru-
ments that are not suitable might damage the MIU central control unit. Use instruments with definitions
over 0.1V and 0.5 W , the precision must be greater than 2%.