Stator Check - APRILIA SR MAX 125 ie Service Station Manual

Table of Contents

Advertisement

SR MAX 125 ie
Voltage value
> 5 Volt
- HV coil
With the control unit and HV coil connected, meas-
ure the voltage of the coil primary during the start-
up test with the voltage peak adaptor and con-
necting the positive terminal to the ground one and
the negative to the coil positive connector.
If non-conforming values are measured, replace
the control unit.
NOTE
THE PLASTIC CAP OF THE POSITIVE TERMINAL ON THE
HV COIL PRIMARY IS BLACK AND THE NEGATIVE TER-
MINAL ONE IS GREEN.
Electric characteristic
High voltage coil voltage value
High voltage coil voltage value: > 100 Volt

Stator check

Disconnect the connector from the voltage regulator and check there is continuity between any yellow
cable and the other two cables.
Electric characteristic
Ohm value:
0.7 ÷ 0.9 Ohm