Hirschmann MACH 100 User Manual page 56

Industrial ethernet (gigabit-)switch
Hide thumbs Also See for MACH 100:
Table of Contents

Advertisement

PROFINET IO
Byte
Content
8
Power supply unit 8
9
Signal contact 1
10
Signal contact 2
11
Temperature
12
Fan
13
Module removal
14
ACA removal
15
HIPER_Ring
16
Ring/Network coupling ro
17
Connection
Table 13: Device status
Byte
Content
0
Report port error
Table 14: Port status/parameters
56
Acces
Value Meaning
s
ro
0
Unavailable
1
OK
2
Error
ro
0
Unavailable
1
Closed
2
Open
ro
0
Unavailable
1
Closed
2
Open
ro
0
Unavailable
1
OK
2
Threshold value for temperature exceeded or
not reached
ro
0
Unavailable
1
OK
2
Fan failure
ro
0
Unavailable
1
OK
2
A module has been removed.
ro
0
Unavailable
1
OK
2
The ACA has been removed.
ro
0
Unavailable
1
OK
2
Redundancy failure.
0
Unavailable
1
OK
2
Redundancy failure.
ro
0
Unavailable
1
OK
2
Connection failure.
Acces
Value Meaning
s
rw
0
Do not send alarms
1
Send alarm if one of the following alarm
reasons occurs.
3.2 PROFINET IO Parameters
UM IndustProtocol
Release 9.0 02/2015

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents