EtherNet/IP
Configuration of a PLC using the example of Rockwell
software
Open the "EDS Hardware Installation Tool" of RSLinx.
Use the "EDS Hardware Installation Tool" to add the EDS file.
Restart the "RSLinx" service so that RSLinx takes over the EDS file of
the Switch.
Use RSLinx to check whether RSLinx has detected the Switch.
Open your Logix 5000 project.
Integrate the Switch into the Ethernet port of the controller as a new
module (Generic Ethernet Module).
Setting
Comm Format:
IP Address
Input Assembly Instance
Input Size
Output Assembly Instance
Output Size
Configuration Assembly Instance 3
Configuration Size
Table 2:
Settings for integrating a Generic Ethernet Module
18
2.1 Integration into a Control System
I/O connection
Input only
Data - DINT
Data - DINT
IP address of the
IP address of the
Switch
Switch
2
2
7
7
(MACH 4000: 11)
(MACH 4000: 11)
1
254
1
0
(MACH 4000: 2)
3
0
0
Listen only
Input data - DINT -
Run/Program
IP address of the
Switch
2
7
(MACH 4000: 11)
255
0
3
0
UM IndustProtocol
Release 9.0 02/2015