Recommendations for Cross Channel Phase

When conducting a cross channel phase analysis, we recommend you:
1.
Determine the exact frequency of interest. To do this, you can use
spectra to identify high amplitude peaks at specific frequencies.
2.
Position the channel 1 sensor in a location which has high vibration
at this frequency. Do NOT move this sensor once testing has started.
3.
Try out different locations with the channel 2 sensor, noting the
phase and amplitude relationships compared to the fixed channel 1
position.
4.
Repeat steps 2 and 3 at any other locations of interest.
Section 4 — Measurement Types and their Uses