Save Multi-channel Measurements

If you wish to transfer your measurements to Ascent, be aware that the
program identifies recordings by their location and date/time stamps. If
two or more recordings are taken at the same time and saved to the
same location, they will have identical date/time stamp and location
details. This will cause Ascent to delete one of your measurements. To
prevent this, we recommend you store your recordings in measurement
locations that reflect the direction the sensors were placed when the
measurement was taken.
To save multi-channel measurements:
1.
Press
when you are ready to stop measuring.
2.
Press
Save — This opens the Select Location to Save menu.
3.
Press Save to on the right beside the channel you wish to save.
4.
Use the arrow keys to select an existing location to save the
measurement to, or press
NOTE: You can save each channel's measurements or select only
those you wish to keep.
5.
Press
to return to the Select Locations menu.
6.
Repeat steps 3 to 5 to store your other measurement(s).
TIP: To undo saving of a measurement, press the channel's Save
key again — The text will change to Don't Save.
7.
Press
when you have selected all the measurements you want
to save — Your instrument will display Data Saved before returning
to the measurement screen.
Section 4 — Measurement Types and their Uses
to create a new location.
108