Demod Spectrum

To use the Demod Spectrum:
1.
Press
or
2.
Press
Demod.
3.
Use the arrow keys on the left to select a parameter set or press
to create a new one > Set the parameters as required.
NOTE: Ensure you set the bandwidth first, as this will determine the
range of available Fmax values.
4.
Press
to start measuring.
6Pack
6Pack supports up to six measurements. You can take these
simultaneously from a single data stream/channel (across a maximum
of three channels). All standard condition monitoring data can be
acquired in one step, in the time normally required to take a single
conventional recording.
A 6Pack recording may include some or all of the following
measurement types for each recorded channel:
High Frequency Spectrum
High Frequency Waveform
Low Frequency Spectrum
Low Frequency Waveform
Demodulation Spectrum
Demodulation Waveform