Warnings; Technical.specifications; Layout.and.components.of.624.Bld; Description.of.components - FAAC 624BLD Manual

Hide thumbs Also See for 624BLD:
Table of Contents

Advertisement

1..

WARNINGS

Attention: Before attempting any work on the control unit (connections, maintenance), always turn off power.
- Install, upstream of the system, a differential thermal breaker with adequate tripping threshold.
- Connect the earth cable to the terminal on the J9 connector of the unit (see fig.2).
- Always separate power cables from control and safety cables (push-button, receiver, photocells, etc.). To avoid any electrical noise, use
separate sheaths or a screened cable (with the screen earthed).
2..

TECHNICAL.SPECIFICATIONS.

P o w e r s u p p l y v o l t a g e
A b s o r b e d p o w e r
M o t o r m a x . l o a d
P o w e r s u p p l y f o r
a c c e s s o r i e s
A c c e s s o r i e s m a x .
c u r r e n t
Operating am b i e n t
t e m p e r a t u r e
F u s e s
F u n c t i o n l o g i c s
W o r k t i m e
P a u s e t i m e
M o t o r p o w e r
T e r m i n a l b o a r d i n p u t s
Closing safety devices, Stop, Emergency,
Opening and closing limit-switch, Detector
C o n n e c t o r i n p u t s
Motor capacitor, Beam detachment sensor
T e r m i n a l b o a r d
Power supply 4 Vdc, Fail-safe, Status output,
o u t p u t s
R a p i d c o n n e c t o r
P r o g r a m m i n g
Logics, Pause Time, Power, Loop  and , Thrust
torque, Pre-flashing, Slow closure, Deceleration
P r o g r a m m a b l e
time, Work time, Indicator light output, Fail-safe
f u n c t i o n s
output, Status output, BUS output, Assistance
CONTROL UNIT
30 Vac (+6% -0%) - 50 Hz
7 W
300 W
4 Vdc
500 mA
-0°C - +55°C
F = F 5A - 50V F = T 0.8A - 50V
Automatic, Automatic , Semiautomatic,
Parking, Parking-Automatic,
Condo, Condo-automatic
FAAC-CITY, Dead-man, Remote, Custom
Programmable (from 0 to 4 minutes)
Programmable (from 0 to 4 minutes)
Programmable on 50 levels
Loop, Loop, Open, Close,
Power supply 30Vac + Earth
Flashing light, Fan, Motor,
Indicator light 4 Vdc, BUS
5-pin Minidec board coupling, Decoder,
Receiver RP/RP
No. 3 keys (+, -, F) and display
request
624 BLD
3..

LAYOUT.AND.COMPONENTS.OF.624.BLD

TF1
F2
+
-
DL
F
J4
LOOP DETECTOR
J11C

3.1.DESCRIPTION.OF.COMPONENTS

DL
SIGNALS AND PROGRAMMING DISPLAY
LED
INPUT STATUS CONTROL LEDs
J1
LOW-VOLTAGE TERMINAL BOARD
TERMINAL BOARD FOR CONNECTION OF MOTOR,
J2
FLASHING LIGHT AND FAN
J3
OPENING LIMIT-SWITCH CONNECTOR
J4
CONNECTOR: DECODER
J5
CLOSING LIMIT-SWITCH CONNECTOR
CONNECTOR FOR ROD BREAKING SENSOR
J6
J8
CONNECTOR FOR MOTOR THRUST CAPACITOR
J9
TERMINAL-BOARD FOR 30 VAC POWER SUPPLY
J11
CONNECTOR FOR EXTERNAL LOOP DETECTOR
FUSE FOR MOTORS AND TRANSFORMER PRIMARY
F1
WINDING (F 5A)
F2
FUSE FOR L OW VOL T AGE AND ACCESSORIES (T 800mA)
F
PROGRAMMING PUSH-BUTTON "F"
+
PROGRAMMING PUSH-BUTTON "+"
-
PROGRAMMING PUSH-BUTTON "-"
TF1
TRANSFORMER
3
F1
J9
J8
J2
EMERG - DL5
STOP - DL4
FSW - DL3
J1
CLOSE - DL2
LED
OPEN - DL1
PIVOT - DL8
FCA - DL6
FCC - DL7
J6
J3
J5
J11A
J11B
Fig. 1
MINIDEC / RP RECEIVER

Hide quick links:

Advertisement

Table of Contents
loading