Example 2:
Enabling the FFB:
Enabling individual FFB including assigning a priority:
P2801[3] = 2
P2801[4] = 2
P2802[3] = 3
P2801[0] = 1
The FFB are calculated in the following sequence:
Timer 4, OR 1, OR 2, AND 1
The function blocks are interconnected using BICO technology (refer to Section
3.1.2.3). In so doing, the function blocks can be connected with one another as
well as to other signals and quantities as long as these signals / quantities have the
appropriate attribute (BO, BI, CO and CI).
MICROMASTER 440
Operating Instructions
6SE6400-5AW00-0BP0
P2800 = 1
OR 1
OR 2
Timer 4
AND 1
3 Functions
195