3 Functions
DIN4
Terminals
BOP
ADC
MOP
Drive data set (DDS) bit 0
P0820 = ...
Selects the command source from which bit 0 should be read-out to select a drive data set.
Operation
Ready
Select DDS
BI: DDS bit 1
P0821
(0:0)
BI: DDS bit 0
P0820
(0:0)
Active DDS
r0051[1]
The currently active drive data set (DDS) is displayed using parameter r0051[1]:
Most frequent settings:
722.0 = Digital input 1 (P0701 must be set to 99, BICO)
722.1 = Digital input 2 (P0702 must be set to 99, BICO)
722.2 = Digital input 3 (P0703 must be set to 99, BICO)
722.3 = Digital input 4 (P0704 must be set to 99, BICO)
722.4 = Digital input 5 (P0705 must be set to 99, BICO)
722.5 = Digital input 6 (P0706 must be set to 99, BICO)
722.6 = Digital input 7 (via analog input 1, P0707 must be set to 99)
722.7 = Digital input 8 (via analog input 2, P0708 must be set to 99)
128
P0810 = 722.3
P0700[0] = 2
0
1
P0700[1] = 1
P1000[0] = 2
0
1
P1000[1] = 1
3
2
1
0
Changeover time
approx. 50 ms
3
2
1
0
Select
DDS
r0055
r0054
r0051 [0]
bit05
bit04
1. DDS
0
0
2. DDS
0
1
3. DDS
1
0
3. DDS
1
1
Sequence control
Setpoint
Motor
channel
control
Changeover time
approx. 50 ms
Active
DDS
r0051 [1]
0
0
1
1
2
2
2
2
MICROMASTER 440
Issue 10/06
0
t
CO/BO: Act CtrlWd2
r0055
.05
r0055
.05
CO/BO: Act CtrlWd2
r0055
.04
r0055
.04
t
CO: Active DDS
.01
r0051 [2]
t
Operating Instructions
6SE6400-5AW00-0BP0