Figure 4.198 - Monitoring > sFlow > sFlow Global Settings
sFlow State: Specify to enable or disable the sFlow feature.
Click Apply to make the configurations take effect.
Monitoring > sFlow > sFlow Analyzer Server Settings
The Switch can support 4 different Analyzer Servers at the same time and each sampler or poller can select
a collector to send the samples. We can send different samples from different samplers or pollers to different
collectors.
This sFlow Analyzer Server Settings page allows user to configure the sFlow analyzer server configuration.
Figure 4.199 - Monitoring > sFlow > sFlow Analyzer Server Settings
Analyzer Server ID (1-4): The analyzer server ID specifies the ID of a server analyzer where the packet will
be forwarded.
Owner Name: The entity making use of this sFlow analyzer server. When owner is set or modified, the
timeout value will become 400 automatically.
Timeout (1-2000000): The length of time before the server times out. When the analyzer server times out,
all of the flow samplers and counter pollers associated with this analyzer server will be deleted. If not
specified, its default value is 400. Tick the Infinite check box to have unlimited time.
Collector (IPv6) Address: The IP address of the analyzer server. If not specified or set a 0 address, the
entry will be inactive.
Collector Port (1-65535): The destination UDP port for sending the sFlow datagrams. If not specified, the
default value is 6343.
Max Datagram Size (300-1400): The maximum number of data bytes that can be packed in a single sample
datagram. If not specified, the default value is 1400.