Provisioning The Lrm; Alarms And Events - Symmetricom SSU-2000 User Manual

Synchronization supply unit and the synchronization distribution unit
Hide thumbs Also See for SSU-2000:
Table of Contents

Advertisement

Provisioning the LRM

The following information provides examples of how to use ICS and TL1 commands
to provision an LRM in an SSU-2000. Refer to
266, and
Interactive Command
commands.
Examples
The following ICS commands enable port 2 on an LRM in slot 8 of shelf 3, set the
line build-out to 399 feet, and set the slip error threshold to 6:
LRM 3A8-2 ENABLE
LRM 3A8-2 LBO 399
LRM 3A8-2 SLIP 6
SET-PRMTR-LRM::S3A8-2:::ON,399,6,,;
The following ICS commands enable port 3 of an LRM in slot 11 of shelf 2 and
enables a FAULT strategy,:
LRM 2A11-3 FLT AIS
SET-PRMTR-LRM::S2A11-3:::ON,,,,,AIS;
The following ICS commands set the circuit ID of port 4 on an LRM in slot 7 of shelf
1 to 1A7-4:
LRM 1A7-4 CID 1A7-4
SET-PRMTR-LRMCID::S1A7-4:::1A7-4;

Alarms and Events

The LRM generates the alarms and events listed in
respectively.
12713020-002-2 Revision D – April 2004