Installing The Cut-Through Assembly In The Sdu-2000 - Symmetricom SSU-2000 User Manual

Synchronization supply unit and the synchronization distribution unit
Hide thumbs Also See for SSU-2000:
Table of Contents

Advertisement

Output Module Reference Data
Line Retiming Unit (LRU)
Installing a CTA in the SDU-2000
The SDU-2000 shelf has I/O interface connections on the rear panel for connecting
the SDU-2000 to the corresponding I/O adapter panels. The LRM I/O connections
are made from the 50-pin Micro-D female connectors on the rear panel of the
SDU-2000, through the CTA, and to the adapter panel using the appropriate cable.
Connectors J1 through J14 are labeled OUT-1 through OUT-14 and each connector
is associated with a specific I/O plug-in module slot. Symmetricom recommends
using connectors J5 through J12, which correspond to module slots A5 through A12
respectively (see
Figure
8-22).
Figure 8-22. Installing the Cut-Through Assembly in the SDU-2000
Use the following steps to install the Cut-Through Assembly on an SDU-2000. Refer
to
Table 8-17
for a description of the SSU-2000 and CTA I/O connector pin functions
and to
Figure 8-23
for pin orientation.
12713020-002-2 Revision D – April 2004
SSU-2000 User's Guide 213