Functional Specifications; Stratum 2E Clock Module Specifications - Symmetricom SSU-2000 User Manual

Synchronization supply unit and the synchronization distribution unit
Hide thumbs Also See for SSU-2000:
Table of Contents

Advertisement

Table 6-1. Stratum 2E Clock Module Status LED Indicators (Continued)
Indicator
Color
Warmup
Amber
Acquire
Green
Locked
Green
Holdover
Amber

Functional Specifications

Table 6-2
lists the specifications for the Stratum 2E Clock module.
Table 6-2. Stratum 2E Clock Module Specifications
Performance Characteristic
Free Running Accuracy
Holdover Stability (Rubidium LO)
0 to 24 hrs, @ +10 to +50
0 to 24 hrs, @
0 to +50
30 days @ +10 to +40
30 days @
0 to +50
Numeric Controlled Oscillator
(NCO) PLL lock range
Tuning Resolution (Locked Mode)
Warm-up Time (Warm-up Mode)
Wander Output (Holdover)
Jitter (Locked or Holdover)
12713020-002-2 Revision D – April 2004
On = Clock module is in warm-up mode
Off = Clock module has completed warmup
On = Clock module is acquiring a lock on a signal
Off = Not acquiring a lock on a signal
On = Clock module is locked on a signal
Off = Clock module is not locked on a signal
On = Clock module is in Holdover mode of operation
Off = Clock module is not in Holdover mode
Within ±5 x 10
Within ±5 x 10
°
C
±9 x 10
°
C
±1 x 10
°
C
±1.5 x 10
°
C
±1.7 x 10
±5 x 10
<1 x 10
20 minutes
Includes effects of all SSU-2000 modules:
Compliant with clock levels per ITU-T G.812, T1.101-1999,
and Telcordia Technologies GR-378-CORE and
GR-1244-CORE. Meets SONET requirements per T1.105.
Meets or exceeds performance requirements for ITU-T
G.812 Type II and ETSI Transit Node clocks and T1.101 and
Telcordia Technologies (Bellcore) Stratum 2 clocks.
< 4 ns p-p (measured at the CLKA/BIN 8kHz output)
Description
Specification
-10
the first year
-9
after 10 years
-11
-10
-10
-10
-4
-13
Clock Module Reference Data
Stratum 2E Clock Module
SSU-2000 User's Guide 127

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sdu-2000

Table of Contents