Symmetricom SSU-2000 User Manual page 353

Synchronization supply unit and the synchronization distribution unit
Hide thumbs Also See for SSU-2000:
Table of Contents

Advertisement

Level 2
Level 3
Level 4
Remarks
Related
Restrictions None
Example:
SSU_2000+>mtie 1A10-02
MTIE for 1A09-01, on Clock A:
Start Time: 2001-06-24T19:00:00
Stop Time:
The MTIE (
The MTIE (
The MTIE (
The MTIE (
The MTIE (
The MTIE (
The MTIE ( 10000.00 sec) is 22
The MTIE (100000.00 sec) is 22
2001-06-25T18:20:49
Locked, TL1A
12713020-002-2 Revision D – April 2004
MTIE xAy-z [{A| B}] HISTORY [count]
A| B specifies Clock A or Clock B. The default is the selected clock
output. This command displays the one-day MTIE history for the
last one to 100 days.
Same as Level 1 operation
Same as Level 2 operation
Same as Level 3 operation
Since MTIE involves intensive calculations, you can only specify
one port.
None
2001-06-25T18:20:00
0.05 sec) is 5
0.10 sec) is 5
1.00 sec) is 6
10.00 sec) is 7
100.00 sec) is 12
1000.00 sec) is 13
1A05 Rep Pos Set by Rec, Information
Interactive Command Set
SSU-2000 User's Guide 353

Advertisement

Table of Contents
loading

Related Products for Symmetricom SSU-2000

This manual is also suitable for:

Sdu-2000

Table of Contents