Cranks But Does Not Start - No Spark; Cranks But Does Not Start (Has Sufficient Spark) - Nilfisk-Advance CS7000 Service Manual

Hide thumbs Also See for CS7000:
Table of Contents

Advertisement

Service Manual – Haram Captor II
Cranks but does not start – No Spark
Possible causes:
• Spark Control Module not powered up.
– Ignition request relay
– Woodward L Series Actuator not energizing ignition request relay
– Spark control module ground
• Crank Position Sensor
• Spark Control Module
• Wiring
• Ignition Coils (not likely that all 3 coils would fail at once)

Cranks but does not start (has sufficient spark)

Possible causes:
• No fuel
– Empty tank
– Fuel pump inoperative
– No electrical power to fuel pump
Ignition request fuse – blown
High coolant temp shut down relay – "Closed at rest" contacts not making connection
Open wire on positive or negative side of fuel pump
– No power to carburetor petrol fuel shut off solenoid
• Mechanical engine
– Insufficient compression
– Plugged Intake
– Plugged Exhaust
• Actuator
– Not opening throttle
Engine System - Petrol (Gasoline)