Nilfisk-Advance CS7000 Service Manual page 64

Hide thumbs Also See for CS7000:
Table of Contents

Advertisement

Service Manual – CS7000
The following is an outline of the User Options Menu Default values are bold text or noted.
• 1 Scrub System
– 1 Scrub Mode 1st Use - The default scrub mode used the first time after power up. After first time,
mode is last used.
◦ 1 Light - The scrub mode will default to the Light setting when activated. (DEFAULT)
◦ 2 Heavy - The scrub mode will default to the Heavy setting when activated.
◦ 3 Extreme - The scrub mode will default to the Extreme setting when activated.
– 2 Detergent Start Up - Determines if the detergent system will be activated when the scrub is turned
on.
◦ 1 Off - always disabled when the scrub system is activated.
◦ 2 On - always enabled when the scrub system is activated.
◦ 3 Last State - returned to state when the scrub system was last on.
– 3 Maximum Mode - The maximum scrub mode that the operator can select.
◦ 1 Light - The only available scrub mode will be the Light setting.
◦ 2 Heavy - The Light and Heavy scrub mode will be available.
◦ 3 Extreme - All scrub modes will be available.
– 4 Light Scrub Mode - The light scrub pressure, solution rate and detergent rate can be programmed
depending on its application where high solution rate is needed with light scrub pressure or low
solution rate with heavy scrub pressure.
◦ 1 Scrub Pressure -
− RANGE: 1-MIN, 2-MED, 3-MAX
− DEFAULT: 1-MIN
◦ 2 Solution Flow
− RANGE: Off,1 – 5
− DEFAULT: 1
– 5 Heavy Scrub Mode - The heavy scrub pressure, solution rate and detergent rate can be programmed
depending on its application where a higher solution rate is need with heavy scrub pressure or low
solution rate with heavy scrub pressure.
◦ 1 Scrub Pressure
− RANGE: 1-MIN, 2-MED, 3-MAX
− DEFAULT: 2-MED
◦ 2 Solution Flow
− RANGE: 1 – 5
− DEFAULT: 2
– 6 Extreme Scrub Mode - The extreme scrub pressure, solution rate and detergent rate can be
programmed depending on its application where a higher solution rate is need with extreme scrub
pressure or low solution rate with extreme scrub pressure.
◦ 1 Scrub Pressure
− RANGE: 1-MIN, 2-MED, 3-MAX
− DEFAULT: 3 - MAX
Control System
64