Fault History - Nilfisk-Advance CS7000 Service Manual

Hide thumbs Also See for CS7000:
Table of Contents

Advertisement

Service Manual – CS7000
Flash
Programmer LCD
Code
Display/ Effect Of Fault
#
93
Encoder LOS (Limited
Operating Strategy)
Enter LOS control mode.
94
Emer Rev Timeout
ShutdownEMBrake;
ShutdownThrottle.
98
Illegal Model Number
ShutdownMotor;
ShutdownMainContactor;
ShutdownEMBrake;
ShutdownThrottle;
FullBrake; ShutdownPump.
99
Dualmotor Parameter
Mismatch
Note: Not used on CS7000

Fault History

The 1311 programmer can be used to access the controller's fault history file. The programmer will read out
all the faults the controller has experienced since the last time the fault history file was cleared. Faults such
as contactor faults may be the result of loose wires; contactor wiring should be carefully checked. Faults such
as over temperature may be caused by operator habits or by overloading.
Troubleshooting Chart
Possible Cause(s)
1.
Limited Operating Strategy
control mode has been
activated, a result of either an
Encoder (Code 36) or a Stall
Detect (Code 73).
2.
Motor encoder failure.
3.
Bad crimps or faulty wiring.
4.
Vehicle is stalled.
1.
Emergency Reverse was
activated and concluded
because the EMR Timeout
timer has expired.
2.
The emergency reverse input
is stuck On.
1.
Model_Number variable
contains illegal value (not
1234, 1236, 1238, or 1298).
2.
Software and hardware do not
match.
3.
Controller defective.
1.
Dual Drive fault: see Dual
Drive manual.
Wheel System, Traction
Set/Clear Conditions
Set: Encoder Fault (Code 36)
or Stall Detect Fault (Code
73) was activated, and Brake
or Interlock has been applied
to activate LOS control mode,
allowing limited motor control.
Clear: Cycle KSI or, if LOS
mode was activated by the
Stall Fault, clear by ensuring
encoder senses proper
operation, Motor RPM = 0, and
Throttle Command = 0.
Set: Emergency Reverse was
activated and ran until the
EMR Timeout timer expired.
Clear: Turn the emergency
reverse input Off.
Set: Illegal Model_Number
variable; when KSI cycles,
a check is made to confirm
a legal Model_Number, and
a fault is issued if one is not
found.
Clear: Download appropriate
software for your controller
model.
428

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents