Event: Recording with Memory Cleared
When a recording starts, the logger will continue to record until one of the
following occurs:
The Session is complete.
The Memory is full and the recording mode is Start/Stop.
The
PRESS button is pushed until the STOP (ORANGE) LED
lights up and is released before the next LED lights.
The Stop Recording command from the SLII Control Panel is sent
to the unit.
The battery voltage falls below 1.7V.
Event: Recording with a Partial or Full Memory
If the RED LED is double-blinking, the memory must be cleared before
any further recording can be performed.
If the RED LED is single-blinking prior to starting a New Recording Ses-
sion, the memory is partially full.
To save, clear or check memory availability, use the Simple Logger
Control Panel software.
There may be instances where the GREEN LED is also double-blinking
indicating that the logger is still recording. The user can choose to stop the
Recording Session and download the saved session(s) and/or erase the
memory.
NOTE: The logger memory cannot be erased while in the Record mode. The
recording must be stopped first.
Event: Memory Filled During Recording Session
If the logger is recording using the Start/Stop mode and memory is filled
before the Recording Session has finished, the session will end.
The following happens:
The GREEN LED single-blinks.
The RED LED double-blinks.
At this time:
The memory can be downloaded and erased.
A new recording can be started or scheduled once the memory is
erased.