2. Five LED Indicators
The LEDs on the instrument serve two functions: control operation
and status function.
The control operation (function when holding down the PRESS
button) is indicated with text to the left of each LED.
The status function (function when PRESS is not being held down)
associated with each LED is indicated with text to the right of each
LED.
Refer to § 4.1 for detailed descriptions of each LED.
3. Female Type Mini-B USB Connector
4. Reset Button (not shown)
The RESET button resets the CPU and is located in the battery com-
partment To access this button, remove the battery compartment
cover, then reset the instrument by inserting a small tool (such as a
paper clip) through the hole in the case to activate it.
5. Flash Upgrade Switches (not shown)
These two switches (accessible from under the battery compartment),
along with the RESET button (and PC software), are used to recover
from a failed flash upgrade procedure.
WARNING: If the RESET button is pressed when the logger is recording, it will
stop recording and data in memory may be lost.