  • Page 1 CL601 SIMPLE LOGGER ®  TRMS CLAMP-ON MODEL E N G L I S H User Manual ShopAEMC www. .com 1.888.610.7664 Shop for AEMC products online at:...
  • Page 2 12 months and begins on the date of receipt by the customer. Serial #: ________________________________ Catalog #: 2126.01 Model #: CL601 Please fill in the appropriate date as indicated: Date Received: _________________________________ _______________________ Date Calibration Due: ShopAEMC www. .com 1.888.610.7664 Shop for AEMC products online at:...
  • Page 3: Table Of Contents

    4.4 Recording Data ...............13 4.4.1 Starting a Recording Session ........13 4.4.2 Stopping a Recording Session ........13 4.5 Downloading Recorded Data ..........13 4.6 Clearing Alarm Indication ............14 4.7 Erasing Data from Memory .............14 4.8 Data Storage ................15 4.8.1 Trend Measurements ..........15 4.9 Normal Operation ..............15 4.10 R eset Switch Operation ............18 ShopAEMC www. .com 1.888.610.7664 Shop for AEMC products online at:...
  • Page 4 5. MAINTENANCE ................19 5.1 Changing the Batteries ............19 APPENDIX A: TROUBLESHOOTING ............20 APPENDIX B: GLOSSARY ..............21 Limited Warranty ...................23 Warranty Repairs ...................23 ShopAEMC www. .com 1.888.610.7664 Shop for AEMC products online at:...
  • Page 5: Introduction

    Refers to a type B current sensor. Do not apply around or remove from HAZARDOUS LIVE conductors without additional protective means (de-energizing the circuit or wearing protective clothing suitable for high voltage work). In conformity with WEEE 2002/96/EC Simple Logger II Model CL601 ® ShopAEMC www. .com 1.888.610.7664 Shop for AEMC products online at:...
  • Page 6: Definition Of Measurement Categories

    Notify your distributor of any missing items. If the equipment appears to be damaged, file a claim immediately with the carrier and notify your distributor at once, giving a detailed description of any damage. Save the damaged packing container to substantiate your claim. Ordering Information Simple Logger II Model CL601 ........Cat. #2126.01 ® (1-Channel, TRMS Clamp-on 600A Includes USB cable, DataView CD-ROM, 2x1.5V AA-cell alkaline batteries, user manual ®...
  • Page 7: Product Features

    CHAPTER 2 PRODUCT FEATURES Description The Simple Logger II Model CL601 is a battery powered, one channel ® recording device with an alkaline battery pack. Line tracking is performed such that 64 samples over one line cycle are taken. Frequency tracking is performed over the range of ±2Hz around the nominal line frequency (50 or 60Hz). Harmonic measurements are calculated from these 64 samples (Harmonics are only available from the Simple Logger II Control Panel ® within the DataView application). ® The Simple Logger II records TRMS at a rate of up to eight times per ®...
  • Page 8: Control Features

    Control Features Figure 2-1. Key Components and Features 1. Control Button (PRESS) This button marked “PRESS” selects the mode of operation. Use this button to start or stop recordings, erase the memory, clear alarms and turn the instrument ON/OFF. Simple Logger II Model CL601 ® ShopAEMC www. .com 1.888.610.7664 Shop for AEMC products online at:...
  • Page 9 WARNING: If the RESET button is pressed when the logger is recording, it will stop recording and data in memory may be lost. Simple Logger II Model CL601 ® ShopAEMC www. .com 1.888.610.7664 Shop for AEMC products online at:...
  • Page 10: Specifications

    If the unit is connected to DataView via a PC, the battery life is 100 hours regardless ® of the storage rate. Simple Logger II Model CL601 ® ShopAEMC www. .com 1.888.610.7664 Shop for AEMC products online at:...
  • Page 11: Mechanical

    Drop: IEC 68-2-32 (1m) Environmental Operating Temperature: 14° to 122°F (-10° to 50°C) Storage Temperature: -4° to 140°F (-20° to 60°C) Relative Humidity: 0 to 85% @ 95°F (35°C), Non-condensing Altitude: 2000m Safety 600V Cat. III 300V Cat. IV *All specifications are subject to change without notice Simple Logger II Model CL601 ® ShopAEMC www. .com 1.888.610.7664 Shop for AEMC products online at:...
  • Page 12: Operation

    While the instrument is OFF, it will momentarily turn ON for each scheduled sample interval. This operation will make sure that a scheduled recording will begin and sample intervals will be stored even while the instrument is OFF. The control operation of each LED is as follows: • GREEN: Starts a recording • ORANGE: Stops a recording • YELLOW: Clears the alarm state • RED: Erases the memory • BLUE: Turns the instrument OFF Simple Logger II Model CL601 ® ShopAEMC www. .com 1.888.610.7664 Shop for AEMC products online at:...
  • Page 13 Both of these modes have low power states, which require very little power from the battery. The LEDs will not blink at this time. By using these low power states, the instrument can be programmed to start recording at some time in the future without draining the batteries. • SLEEP mode: The instrument enters the low power state if the button is not pressed for one minute. It will remain in this state until either the button is pressed or the internal clock reaches the start time for a scheduled recording. • RECORD mode: The instrument enters the low power state between sample sets. The slower the storage rate, the greater the portion of time the instrument is in the low power state. Thus, the slower the storage rate, the longer the instrument can record. Simple Logger II Model CL601 ® ShopAEMC www. .com 1.888.610.7664 Shop for AEMC products online at:...
  • Page 14: Connecting The Simple Logger ® Ii To A Computer

    The instrument contains protection circuitry to prevent it from being turned on when the battery voltage is below 1.7V. There are two thresholds for the battery voltage: • The first is used to indicate low battery. The low battery indicator will blink when the battery voltage drops below 1.8V. • The second is used to determine when to terminate recording and turn the unit off. The shutdown threshold is when the battery voltage drops below 1.7V. Simple Logger II Model CL601 ® ShopAEMC www. .com 1.888.610.7664 Shop for AEMC products online at:...
  • Page 15: Recording Data

    Recorded measurements stored in the instrument are transferred to a computer via the download command in the SLII Control Panel. For instructions on downloading data, see the Downloading Recorded Instru- ment Data section inside the DataView manual. ® Simple Logger II Model CL601 ® ShopAEMC www. .com 1.888.610.7664 Shop for AEMC products online at:...
  • Page 16: Clearing Alarm Indication

    RED LED stops blinking at the fast rate. Erasing the Memory using the SLII Control Panel: 1. Connect the instrument to the computer, then open the SLII Control Panel. 2. Select Erase Memory from the Instrument Menu. Simple Logger II Model CL601 ® ShopAEMC www. .com 1.888.610.7664 Shop for AEMC products online at:...
  • Page 17: Data Storage

    PRESS button is used to Start and Stop a Recording • The Session. PRESS button is not pressed for a period of one minute, • If the the instrument will enter SLEEP mode and wait for either another button press or the recording start time to arrive (if a recording is scheduled). While in SLEEP mode, the LEDs will not blink. • A button press of 0.5 seconds will return the unit back to the normal STANDBY mode. Simple Logger II Model CL601 ® ShopAEMC www. .com 1.888.610.7664 Shop for AEMC products online at:...
  • Page 18 Event: Memory Filled During Recording Session If the logger is recording using the Start/Stop mode and memory is filled before the Recording Session has finished, the session will end. The following happens: • The GREEN LED single-blinks. • The RED LED double-blinks. At this time: • The memory can be downloaded and erased. • A new recording can be started or scheduled once the memory is erased. Simple Logger II Model CL601 ® ShopAEMC www. .com 1.888.610.7664 Shop for AEMC products online at:...
  • Page 19 Under these conditions, it is possible to turn the logger ON from the computer to download the data, if the batteries have sufficient power. The logger is now ready for a New Session or Download. Pressing the PRESS button until the START (GREEN) LED lights up and releasing the button before the next LED lights, will start a New Session depending on the available memory. Simple Logger II Model CL601 ® ShopAEMC www. .com 1.888.610.7664 Shop for AEMC products online at:...
  • Page 20: 4.10 Reset Switch Operation

    The instrument will try to recover normally. However, under certain condi- tions, the clock and memory full state may be reset. Simple Logger II Model CL601 ® ShopAEMC www. .com 1.888.610.7664 Shop for AEMC products online at:...
  • Page 21: Maintenance

    CHAPTER 5 MAINTENANCE Use only factory specified replacement parts. AEMC will not be held ® responsible for any accident, incident, or malfunction following a repair done other than by its service center or by an approved repair center. Changing the Batteries NOTE: It is recommended that all data is downloaded before replacing the batteries. WARNING: Turn the unit off before changing the batteries or loss of recorded data may occur.
  • Page 22: Appendix A: Troubleshooting

    (less than 0.5 seconds). If the LEDs do not flash, then the instrument is OFF. Turn the instrument ON by pressing the PRESS button for two seconds. The LEDs will light solid once the instru- ment has turned on and you may release the button at that time. Symptom: The instrument does not communicate; LED’s blink dimly at a fast rate. Cause, Correction: This is a fault condition that can be resolved by man- ually erasing the memory (refer to §4.7). Simple Logger II Model CL601 ® ShopAEMC www. .com 1.888.610.7664 Shop for AEMC products online at:...
  • Page 23: Appendix B: Glossary

    Hz: Hertz, a unit of measure of frequency equivalent to cycles per second. I/O: Input/output, a device or port capable of sending or receiving digital information. Port: A name given to any connector allowing input or output of information. Processor: A computing device used to calculate and run a set of instructions. Recording session: A recording session is defined as the time and data contained within the starting and ending of a recording. Resolution: The number of bits in which digitized values will be stored. The Simple Logger II has 12-bit resolution. ® Ride-through: Time during which the AC line voltage has dropped sufficiently low to not be able to power the instrument. Zoom: The ability to select a section of the graph and magnify it for better readability. USB: Universal Serial Bus, a communications port used to access the Data Logger via a computer program (Dataview ® Simple Logger II Model CL601 ® ShopAEMC www. .com 1.888.610.7664 Shop for AEMC products online at:...
  • Page 24 ShopAEMC www. .com 1.888.610.7664 Shop for AEMC products online at:...
  • Page 25: Limited Warranty

    ® For full and detailed warranty coverage, please read the Warranty Coverage Information, which is attached to the Warranty Registration Card (if enclosed) or is available at www.aemc.com. Please keep the Warranty Coverage Information with your records. What AEMC Instruments will do: ®...
  • Page 26 Notes: Simple Logger II Model CL601 ® ShopAEMC www. .com 1.888.610.7664 Shop for AEMC products online at:...
  • Page 27 ShopAEMC www. .com 1.888.610.7664 Shop for AEMC products online at:...
  • Page 28 05/08 99-MAN 100308 v4 Chauvin Arnoux , Inc. d.b.a. AEMC Instruments ® ® ShopAEMC www. .com 1.888.610.7664 Shop for AEMC products online at:...

Table of Contents