AEMC Simple Logger CL600 User Manual

Rms clamp-on module

Advertisement

Quick Links

CL600
SIMPLE LOGGER
®
RMS CLAMP-ON MODULE
E N G L I S H
User Manual

Advertisement

Table of Contents
loading

Summary of Contents for AEMC Simple Logger CL600

  • Page 1 CL600 SIMPLE LOGGER ®  RMS CLAMP-ON MODULE E N G L I S H User Manual...
  • Page 2 Owner’s Record The serial number for the Simple Logger Model CL600 is located on the ® back of the instrument. Please record this number and purchase date for your records. RMS CURRENT CLAMP-ON SIMPLE LOGGER MODEL CL600 ® CATALOG #: 2116.11 SERIAL #: _______________________________________________ PURCHASE DATE: ________________________________________ DISTRIBUTOR: ___________________________________________...
  • Page 3: Table Of Contents

    Table of Contents 1. INTRODUCTION ..............2 1.1 International Electrical Symbols .............2 1.2 Receiving Your Shipment ...............3 1.3 Ordering Information ..............3 2. PRODUCT FEATURES ............4 2.1 Indicators and Buttons ..............5 2.2 Inputs and Outputs .................5 3. SPECIFICATIONS ..............6 3.1 Electrical Specifications ..............6 3.2 Mechanical Specifications ..............7 3.3 Environmental Specifications ............7 3.4 Safety Specifications ..............7 4.
  • Page 4: Introduction

    CHAPTER 1 INTRODUCTION Warning These safety warnings are provided to ensure the safety of per- sonnel and proper operation of the instrument. • Read the instruction manual completely and follow all safety information before operating this instrument. • Use caution on any circuit: Potentially high voltages and currents may be present and may pose a shock hazard. • Read the Safety Specifications section prior to using the instrument. Never exceed the maximum voltage ratings given. • Safety is the responsibility of the operator. • For maintenance, use only original replacement parts. • NEVER open the back of the instrument while connected to any circuit or input. • ALWAYS inspect the instrument and lead prior to use. Replace any defective parts immediately. • NEVER use the Model CL600 on electrical conductors rated above 600V in overvoltage category III (CAT III). International Electrical Symbols This symbol signifies that the instrument is protected by double or reinforced insulation. Use only specified replacement parts when servicing the instrument.
  • Page 5: Receiving Your Shipment

    Model CL600 ....Cat. #2116.11 ® (0 to 600Arms Input) Includes software (CD-ROM), 6 ft DB-9 RS-232 cable, 9V Alkaline battery and user manual Order Accessories and Replacement Parts Directly Online Check our Storefront at www.aemc.com for availability RMS Clamp-on Simple Logger® Model CL600...
  • Page 6: Product Features

    CHAPTER 2 PRODUCT FEATURES PRESS SIMPLE LOGGER ® RMS CLAMP-ON LOGGER MODEL CL600 LOGGER OPERATION: 1. Press to Start Logging (Logging = Two Blinks) 2. Press to Stop Logging (Stand-By = One Blink) 3. Press & Hold 5 Seconds to Shut Off (Off = No Blinks) Warning: All Data will be Deleted! Continuous LED Indicates Overload...
  • Page 7: Indicators And Buttons

    Indicators and Buttons The Simple Logger has one button and one indicator. Both are located ® on the front panel. The PRESS button is used to start and stop recordings, turn the logger on and off and to delete data. The Red LED indicates the status of the logger: • Single Blink: STAND-BY mode • Double Blink: RECORD mode • Continuously On: OVERLOAD condition • No Blinks: OFF mode Warning - Delete Data: Pressing the PRESS button for more than 5 seconds will turn the instrument OFF and delete the stored data. Inputs and Outputs Input to the logger is via a split jaw CT. The bottom of the logger has a female 9-pin “D” shell serial connector used for data transmission from the logger to your computer.
  • Page 8: Specifications

    CHAPTER 3 SPECIFICATIONS 3.1 Electrical Specifications Number of Channels: 1 Measurement Range: 0 to 600Arms Input Connection: Split jaw Accuracy: 2% of Readings + Resolution (0 to 400A) 5% of Readings + Resolution (400 to 600A) Resolution: 8 Bit (0.5Arms) Scale Range Maximum Input Resolution 100% 600 Arms 4 Arms 500 Arms 2 Arms 250 Arms 1 Arms 12.5% 125 Arms 0.5 Arms Sample Rate: 4096/hr max; decreases by 50% each time memory is full Data Storage: 8192 readings Data Storage Technique: TXR™ Time Extension Recording™...
  • Page 9: Mechanical Specifications

    3.2 Mechanical Specifications Size: 9-1/4 x 4 x 1-5/8" (235 x 102 x 41mm) Weight (with battery): 17.1 oz Maximum Conductor Size: 1 conductor 1.65" (42mm) 2 conductors 1" (25.4mm) each Case Material: Polycarbonate UL V0 3.3 Environmental Specifications Operating Temperature: -4 to 158°F (-20 to 70°C) Storage Temperature: -4 to 176°F (-20 to 80°C) Relative Humidity: 5 to 95% non-condensing Temperature Influence: 5cts max 3.4 Safety Specifications Working Voltage: EN 61010, 600V, Cat III *All specifications are subject to change without notice RMS Clamp-on Simple Logger®...
  • Page 10: Operation

    CHAPTER 4 OPERATION Software Installation Minimum Computer Requirements • Windows ® • Processor - 486 or higher • 8MB of RAM • 8MB of hard disk space for application, 400K for each stored file • One 9-pin serial port; one parallel port for printer support • CD-ROM drive 1. Insert the Simple Logger CD into your CD-ROM drive. ® If auto-run is enabled, the Setup program will start automatically. If auto-run is not enabled, select Run from the Start menu and type in D:\SETUP (if your CD-ROM drive is drive D. If this is not the case, substitute the appropriate drive letter).
  • Page 11: Recording Data

    *Acrobat Reader - Links to the Adobe web site to download the ® Acrobat Reader. Acrobat Reader most recent version of Adobe ® is required for viewing PDF documents supplied on the CD-ROM. • *Check for Available Software Updates - Opens the AEMC Software update web site, where updated software versions are available for downloading, if necessary. • View User Guide and Manuals - Opens Windows Explorer for ® viewing of documentation files. 3. To install the software, select Simple Logger Software Setup in the top section of the Set-up window, then select Simple Logger, Version 6.xx in the Options section.
  • Page 12: Using The Software

    Using the Software Launch the software and connect the RS-232 cable from your computer to the logger. NOTE: The first time the program is launched you will need to select a language. Select Port from the menu bar and select the Com port (COM 1, 2 3 or 4) you will be using (see your computer manual). Once the software automati- cally detects the baud rate, the logger will communicate with the computer. (ID number of the logger and number of points recorded displayed). Select download to display the graph. (Download takes about 90 sec- onds.) RMS Clamp-on Simple Logger® Model CL600...
  • Page 13: Maintenance

    CHAPTER 5 MAINTENANCE Battery Installation Under normal conditions, the battery will last up to a year of continuous recording unless the logger is restarted very frequently. In the OFF mode, the logger puts almost no load on the battery. Use the OFF mode when the logger is not in use. Replace the battery once a year in normal use. If the logger will be used at temperatures below 32°F (0°C) or is frequently turned on and off, replace the battery every six to nine months. 1. Make sure your logger is turned off (no blinking light) and all inputs are disconnected. 2. Turn the logger upside down. Remove the battery cover by removing the slotted screw. 3. Locate the two-wire (red/black) battery connector and attach the 9V battery to it. Make sure that you observe polarity by lining up the battery posts to the proper terminals on the connector.
  • Page 14: Importing .Txt Files Into A Spreadsheet

    APPENDIX A Importing .TXT Files into a Spreadsheet Opening a Simple Logger .TXT file in Excel The following example used with Excel Ver. 7.0 or higher. 1. After opening the Excel program, select “File” from the main menu and then select “Open”. 2. In the dialog box that appears, browse and open the folder where your logger .TXT files are stored. This will be located in C:\Program Files\Simple Logger 6.xx if you accepted the default choice offered by the logger installation program.
  • Page 15: Formatting The Date And Time

    Arms 35401.49 3.5 35401.49 35401.49 35401.49 13.5 35401.49 35401.49 35401.49 23.5 35401.49 27.5 35401.49 35401.49 34.5 35401.49 Figure A-1. Sample Data Imported into Excel. Formatting the Date and Time Column ‘A’ contains a decimal number that represents both date and time. Excel can convert this number directly as follows: 1. Click on column ‘B’ at the top of the column to select the data, then click on “Insert” from the main menu and select “Columns” from the drop-down menu. 2. Next, click on column ‘A’ at the top of the column to select the data, then click on “Edit” from the main menu and select “Copy” to copy the entire column. 3. Click on cell 1 of column ‘B’ and then click on “Edit” and select “Paste” to insert a duplicate of column ‘A’ into column ‘B’. This is necessary if you want to show the date and time in two separate columns.
  • Page 16 5. In the dialog box that opens, select the “Date” option from the category list on the left. Select the date format you desire and click on “OK” to format the column. 6. Click on the top of column ‘B’, then click on “Format” and select “Cells” from the drop-down menu. 7. In the dialog box that opens, select the “Time” option from the category list on the left. Select the time format you desire and click on “OK” to format the column. Figure A-2 shows a typical spreadsheet with date, time and value displayed. It may be necessary to change the column width to see all the data. 12/02/04 11:45 AM 12/02/04 11:45 AM 12/02/04 11:45 AM 23.5 12/02/04 11:45 AM 27.5 12/02/04 11:45 AM 12/02/04 11:45 AM 34.5 12/02/04 11:45 AM 12/02/04...
  • Page 17: Repair And Calibration

    For instrument repair and calibration: You must contact our Service Center for a Customer Service Authorization Number (CSA#). This will ensure that when your instrument arrives, it will be tracked and processed promptly. Please write the CSA# on the outside of the shipping container. If the instrument is returned for calibration, we need to know if you want a standard calibration, or a calibration traceable to N.I.S.T. (Includes calibration certificate plus recorded calibration data). Ship To: Chauvin Arnoux , Inc. d.b.a. AEMC Instruments ® ® 15 Faraday Drive Dover, NH 03820 USA Phone: (800) 945-2362 (Ext. 360) (603) 749-6434 (Ext. 360)
  • Page 18: Limited Warranty

    Instruments, not by the distributor from ® whom it was purchased. This warranty is void if the unit has been tampered with, abused or if the defect is related to service not performed by AEMC ® Instruments. For full and detailed warranty coverage, please read the Warranty Coverage Information, which is attached to the Warranty Registration Card (if enclosed) or is available at www.aemc.com.
  • Page 20 08/18 99-MAN 100215 v13 Chauvin Arnoux , Inc. d.b.a. AEMC Instruments ® ® 15 Faraday Drive • Dover, NH 03820 USA • Phone: (603) 749-6434 • Fax: (603) 742-2346 www.aemc.com...

Table of Contents