2.3.3
Transducers for TNC 151.R/TNC
155.R
For cable lengths which exceed 20 m between transducers and control or for transducers which exceed
3040 mm, the control versions TNC 151 .R/TNC
155.R are used.
2.3.3.1
Transducers and EXE-units
for the X, Y, Z-axes
Transducers for the main axes X, Y, Z are connected to TNC 151 .R/TNC
155.R via 3-axis EXE-units
with
separate voltage supply.
The max. cable length between EXE 8 . . and TNC 151 .R/TNC
155.R is 50 m and 20 m between the transducer
and the EXE. Th.e total cable length is therefore 70 m.
2.3.3.2
Transducers and EXE-units
for axis IV
Subdivision
within
the pulse shaping electronics
is always 5-fold.
a) Control of a rotary axis
Rotary encoder with
EXE, with
1 max. cable length EXE / TNC
18 000 lines
subdivision
ROD 250 / ROD 700
801, 5-fold
50 m connecting
cable
RON 255 / RON 705
ROD 250 / ROD 700
602 D, 5-fold
1 m cable on EXE +
RON 255 / RON 705
9 m extension
ROD 271
Pulse shaping stage
RON 275
within
ROD
1 m cable on ROD +
9 m extension
When using a rotary encoder with integral pulse shaping electronics
or the pulse shaping electronics
unit
EXE 602 D, the voltage supply is provided by the TNC 151 .R/TNC
155.R.
In order to maintain the correct supply voltage, the total length of the connecting
cable between EXE 602 D
and the control
is limited to 10 m.
b)
Controll of a linear axis
Transducer
Grating pitch/
Line number
EXE, with
signal subdivision
max. cable length
EXE/TNC
LS 107, LS 107 c
20 j.,tm
801, 5-fold
50 m Extension cable
LS 704, LS 704 c
LS 403, LS 403 c
LS 404, LS 404 c
LS 107, LS 107 c
20 pm
602 D, 5-fold
1 m cable on EXE +
LS 704, LS 704 c
9 m extension
LS 403, LS 403 c
LS 404, LS 404 c
ROD 450
50 x Spindle pitch in mm
801, 5-fold
50 m connecting
cable