6.2
Matchine parameters which require optimization
during commissioning
and preliminary
values
6.2.1
Common machine parameters for both ramp characteristics
Function
Parameter
Possible
I
I
No.
entry values
,Countiq
direction
X
20
i
I
Oor 1
Y
21
Z
22
IV
23
Polarity of nominal
value voltage
X
24
Y
25
Z
26
Oor 1
IV
27
Software limit switch
of remaining nominal
value voltage with error
display
POSITIONING
ERROR
ranges
x+
X-
Y+
Y-
z+
Z-
Ivt
IV-
51
Analogue voltage with
52
44
45
46
47
48
49
50
- 30 000.000 . . .
+ 30 000.000
CmmJ
rapid traverse
Acceleration
54
0.001 . . . 1.5 [ml&J
1 as of software
Circular II~
Integral factor
X
28
0 . . .65
535
Y
29
Z
30
IV
31
Waiting time for cutout
185
0...65,535[s]
Preliminary
Optimised
entry values
entry values
0
.
0
0
0
+ 30 000.000
- 30 000.000
+ 30 000.000
- 30 000.000
+ 30 000.000
- 30 000.000
+ 30 000.000
- 30 000.000
_
9
Enter 0.2 if
machine-dependant
value is unknown
Enter 0.1 when
machine-dependent
value is unknown
9
51