HEIDENHAIN TNC 151 Q Mounting Instructions page 20

Contouring control
Table of Contents

Advertisement

b)
Analogue voltage output of spindle speeds (0 to 99 999 rpm)
outputs
PLC-Allocation
TNC 151 B /
TNC 155 B
Multipoint
connector
TNC 151 Q /
TNC 155 Q
Multipoint
connector
PLC-
Power board
TNC 151 Q/
TNC 155 Q
Multipoint
connector
Control
Spindle analogue voltage
+ 10 volts
-
J4/9
-
J1/9
0 volt
-
J4/10
-
Jl/lO
Gear ratio 1
A7
J2/2
J1/8
-
2
A8
J2/3
Jll9
-
3
A9
J2/4
J1/9
-
4
A10
J2/5
Jl/ll
-
5
All
~-
J2/6
J2ll
-
6
Al2
J2/7
J2/2
-
7
Al3
J2/8
J2/3
-
8
Al4
J2/9
J2/4
-
S-Strobe
A20
J3/3
J2/10
-
Auxiliary
function
completed
El7
J5/7
J5/6
-
Caution
The O-volt nominal value output
must be grounded (see section 3.16 Wiring).
For activation
of the spindle with
DC-servodrive,
the control
provides a DC voltage of 0 to + 10 volts. The polarity
of the output voltage is
determined
by parameter MP172. With the aid of machine parameters 78 to 85, up to 8 gear ratios may be
defined. This shlould be commenced with the entry of the ratio with the lowest speed. The max. voltage at the
input of the servo-amplifier
which is programmed
with machine parameter 87. The S-gating signal is provided
with each gear ratio.
After output of MO3 or M04, the nominal value voltage with the ramp as programmed
with machine para-
meter 168 are output prior to the feedback-signal
"auxiliary
function
completed".
No nominal value
voltage output
takes place with M05.
The nominal value voltage for the spindle drive during gear change is determined
with MP70. For the duration
of gear change, t:he polarity
of this voltage MP70 is switched over in accordance with parameters 124 and 125.
The control
is fitted with an S-Override potentiometer.
The min. and max. voltage values can be programmed
with machine parameters (Nos. 86 to 89 and 184).
3.5
Emergency Stop
In/Output
PLC-Allocation
TNC 151 B/TNC 155 B
TNC: 151 Q/TNC 155 Q
Multipoint
connector
Multipoint
connector
PLC-Power board
Emergency Stop (Output)
-
Emergency stop-test (Input)
E8
Jll8
J3/10
J5/8
J4/4.
Important
functions
of the TNC 151/TNC
155 are under constant supervision through self-diagnostics
(electronic
subassemblies such as microprocessors,
the memory read/write-store,
positioning
systems,
transducers etc.). If a fault is detected, it is indicated as a flashing display in the plain language dialogue.
On output of fault-indication,
the "emergency
stop" contact opens.
The "Emergency
Stop" condition
of TNC 151/TNC
155 can only be cancelled by switching
off the mains
voltage, provided that the fault has been rectified.
A special mains switch may be necessary for the control
only!
20