Transfer Blockwise - HEIDENHAIN TNC 151 Q Mounting Instructions

Contouring control
Table of Contents

Advertisement

6.4.2.3
"Transfer
blockwise"
from a peripheral unit to the TNC 151/TNC
155
In operating modes
.TRANSFER
BLOCKWISE
in SINGLE
BLOCK/AUTOMATIC
PROGRAM
RUN
and
.READ-IN
SELECTED
PROGRAM
data transmission
from the peripheral unit to the TNC 151/TNC
155 is performed
as follows:
Operation/Dialogue
display
Data from
l-NC (out-
put TXD)
Remarks
Data from
peripheral
unit (output
RXD)
-
Select Operating mode
Sinale block/Automatic
Press I+$
Dialogue disolav: PROGRAM
NUMBER
Key-in program
number and enter
into memory with
ENT
•l .-__
--
Dialogue-display
TRANSFER
BLOCKWISE
-
-
-
-
-
-
-
SOH
-
Control transmits SOH
(Beginning o-f heading block)
% = Beginning of program number
The program number may have
1 - 8 digits)
E = Control waits for data input
ETB = End of Transmission
Block
BCC is generated between SOH and
ETB
-
%
Progr.-
--- -
No.
E
ETB
----
BCC
-
DC1 = Start-data transmission
The peripheral
unit transmits
ACK = Data transmission
in order
NAK = Data transmission
erroneous
Repeat heading
The peripheral
unit transmits STX
(Start of text)
_____
DS:
ACK or
NAK
STX
The first program block is transmitted
ETB = End of Transmission
Block
BCC is generated between STX and
Cl-R
Block Text
-~-
ETB
FE----
-
-
-
ACK or
--
NAK
*) In operatiing modes
.Program directory
.Read-in all Iprograms
and
.Read-in program offered
no program number is output
by
the TNC 151/TNC
155
The control transmits
ACK = Data transmission
in order,
next block
NAK = Data transmission
erroneous. Repeat block!
The second program block is
transmitted
-___
STX
Block Text
ETB----
Bee-
--
-
End of Text (program input)
End of Transmission
etc.
ACK or
NAK
etc.
ETX
EOT