Advertisement

Function
Parameter
Possible
Selected
No.
entry values
entry values
Limitation
of S-Override
0..
. 15OC%I
maximum
88
minimurn
89
With these parameters, the limitation
for the S-Override potentiometer
is prograrnmed
(No. 88 maximum,
No. 89 minimum).
After reaching the programmed
limitation
- either max. or min., the S-Analogue
voltage remains constant.
Minimurn
voltage for
S-Analogue output
184
0 . . . 9.999 rv1
With parameter No. 84 the minimum
voltage for S-Analogue output can be programmed.
This minimum
voltage is the permissible minimum
value which will not damage the spindle drive.
Please note:
This limitation
is ineffective
with an activated spindle orientation
option.
Nominal value voltage
70
o . . 9.999 [vJ
for spindle drive during
gear change
Parameter No. 70 permits the programming
of the oscillating voltage output during gear change.
Ramp gradient for S-Analogue
pep~Tm
vQ//ms]
1
With parameter 168 the ascending flank for S-Analogue voltage output can be programmed.
Polarity S-Analogue voltage
Programming
of rpm
S = 0 permitted
172
190
___I---
0
L =
M03: positive voltage
M04: negative voltage
1
* =
M03: negative voltage
M04: positive voltage
2
A =
MO3 and M04-:
positive voltage
3
A =
MO3 and M04-:
negative voltage
-
0
r\ =
S = 0 permitted
1
n =
S = 0 not permitted
Depending on the machine, MP 190 can be programmed
to define whether in addition
to the minimum
output voltage determined
with MP 184, the voltage "0" may be output or not in the lowest gear stage.
Display of current spindle
191
0
n =
no display
rpm before spindle start
1
* =
display
47