6.1.7
Machine parameters for other functions
Function
Parameter
Possible
NO.
entry values
Selected
entry values
Resolution
With parameter 65 the resolution
of TNC 15l/TNC
155 can be programmed
for either 1 urn or 5 pm.
For optimization
of machine parameters, 1 urn is used. The 5 pm resolution
is usually sufficient
for normal
machine operation.
Signal evaluation
X
12
A
1
-
20-fold max. traversing
Y
13
speed 16 [m/min]
Z
14
2
4 =
1 O-fold max. traversing
IV
15
speed 12 [m/min]
With these parameters, the signal evaluation for the transducers can be reduced from 20-fold to 1 O-fold.
Please note:
With IO-fold subdivision
the max. traversing speed is 12 m/min (input frequency
of control 20 kHz).
Standstill
supervision
169
0,001
. 30 [mm]
-i------
Parameter 169 determines the range in which non-controlled
axes may move without
activition
of a fault
detection
signal. If the programmed
limitation
is exceeded, the control then goes into an emergency stop
condition
and indicates the flashing message GROSS POSITIONING
ERROR.
T
--
Movement supervision
234
T
0.03..
10 Cvl
Parameter 234 monitors
machine movement when the programmed
voltage is output.
If no movement
takes place, the control goes into the emergency stop condition
and indicates the flashing message
GROSS POSITIONING
ERROR.
.-
Off-line programming
station
170
0
h =
Control
/\
1
-
Off-line programming
station PLC active
2
A =
Off-line programming
station PLC inactive
Parameter 170 determines whether the control
is intended as an off-line programming
station or not. If
parameter 170 is programmed
with 1 or 2, the control
requires no transducers or external circuitry.
Cancellation
of status display
173
0
A =
Status display is not
with M02, M30 and program
to be cancelled
end
2
1
-
Status display is to
be cancel led
Program conditions
are indicated in the status display of the TNC 151/TNC
155. These status data are required
for re-entry into an amended contour after an operational
interruption.
If these program status data are to be
cancelled at the end of the program, MP173 should be programmed
with "1".
49