8.4
Input/lDutput
diagram for machine parameters
Machine parameters are either keyed or read into an empty memory (commissioning
or control exchange) or
altered at a machine with the control
installed (e.g. switchover
DIALOG/ISO).
Machine parameters should always be stored on an external data medium so that they can be read-in via the
RS-232-C/L/.24-data
interface at any time.
With an empty MP-memory,
the control displays the following
message after power-on:
OPERATING
PARAMTERS
ERASED
After cancelllation of the message via
0
CE , the request for the entry value MPO is displayed
MACHINE
IPARAMETER
MPO ?
Entry is now performed
either manually or via the RS-232-C/V.24
data interface.
Please note
With read-in, the data transmission
mode ME-FE-EXT
is to be set corresponding
to the external storage
unit. This is carried out via the
0
MOD
-key.
8.4.1
Readl-in of machine parameters when memory is erased
Read-in of machine parameters is possible in the ME-mode with the ME 1 Ol/ME
102 magnetic tape units
or the floppy disc unit FE 401.
Before data transmission,
check MOD-function
for correct operating mode.
With FE 401 read-in of machine parameters is also possible in the FE-mode, if these can be called-up via
a program number.
If another peripheral unit is being used instead of the ME or FE, the adaptation
as per ME-operation
is
performed
in the EXT-mode,
however, another Baud rate can be programmed
via the MOD-function.
If the check-sum of the machine parameters is erroneous, the optional dialogue language is always selected
as per the NC-software
number after "Reset".
The memory in which the machine parameters are stored can be erased via the following
code number:
Code number 531210 - Erasing of machine parameters
Simultaneously,
PLC-markers M 1000 to M 2000 are reset.
Read-in of machine parameters via the RS-232-C/V.24-interface
When reading-in machine parameters, comments which are designated by "*"
or ",I' are ignored.