General Information - HEIDENHAIN TNC 151 Q Mounting Instructions

Contouring control
Table of Contents

Advertisement

Transducer
TNC 151/155-version
input
without
separate
PLC-board(s)
Sinusoidal
TNC 151 B/TNC 155 B
signals
TNC 151 F/TNC 155 F"
TNC 151/TNC
155-version
with PLC-board(s)
TNC 151 Q/TNC 155 Q
TNC 151 W/TNC 155 W"
TNC 151 QR/TNC
155 OR
TNC 151 WFVTNC 155 WR"
*without
3D-movement
and "Transfer
blockwise"
We are constantly
working
on the further development
of our TNC-controls.
It is therefore
possible that a
certain control version may deviate from the version described in this manual.
1. General information
The HEIDENHAIN
TNC 151/TNC
l55-controls
are equipped with an integral PLC and are available in two
basic versions:
HEIDENHAINI TNC 151 B/TNC 155 B
These control versions are equipped with a simple interface for connection
to an external PLC. This so-
called "standard
interface"
has remained unchanged since TNC 145, thus making all contouring
controls
compatible.
This standard interface has been realized by a PLC-standard
program. The following
interface description
is
based on this PLC-standard
program.
TNC 151 B/TNC 155 B is supplied with the PLC-standard
program. Certain control
functions
of this PLC-
standard program can be activated via machine parameters.
HEIDENHAIN
TNC 151 Q/TNC 155 Q
Control with a PLC-power board PL 100 B having
.63 inputs,
9 of which have fixed allocations,
.31 outputs
or with PLC-power board PL 110 B having
.63 inputs, 9 o-f which have fixed allocations
25 outputs,
.3 bipolar output pairs
On delivery, this control version also has the standard P LCprogram
stored.
By using a further
PLC-board PL 100 B or PL 110 B, the PLC-inputs and outputs may be doubled.
HEIDENHAIN
TNC 151/TNC 155 - Export versions
TNC 151 F/TNC 155 F, for external PLC.
TNC 151 W/TNC 155 W, with integral PLC and external board
These control versions are identical to the versions TNC 151 B/TNC 155 B and TNC 151 Q/TNC 155 Q with
exception
of the functions
"transfer
blockwise"
and 3D-interpolation.
HEIDENHAIN
TNC 151.R/TNC 155.R
The suffix R indicates that the control versions has squarewave (TTL) signal inputs. Transducer connections
are via an EXE-digitizing
unit.
4

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents