HEIDENHAIN TNC 320 User Manual page 304

Cycle programming
Hide thumbs Also See for TNC 320:
Table of Contents

Advertisement

14.6 SET BASIC ROTATION
(Cycle 404, DIN/ISO: G404)
Cycle run
With Touch Probe Cycle 404, you can set any basic rotation
automatically during program run. This cycle is intended primarily for
resetting a previous basic rotation.
Cycle parameters
U
Preset value for rotation angle: Angular value at
which the basic rotation is to be set. Input range
-360.000 to 360.000
U
Number in table Q305: Enter the number in the
preset table in which the TNC is to save the defined
basic rotation. Input range 0 to 2999
304
Example: NC blocks
5 TCH PROBE 404 BASIC ROTATION
Q307=+0
Q305=1
Touch Probe Cycles: Automatic Measurement of Workpiece Misalignment
;PRESET ROTATION ANG.
;NO. IN TABLE

Advertisement

Table of Contents
loading

Table of Contents