HEIDENHAIN TNC 320 User Manual page 294

Cycle programming
Hide thumbs Also See for TNC 320:
Table of Contents

Advertisement

U
Traversing to clearance height Q301: Definition of
how the touch probe is to move between the
measuring points:
0: Move at measuring height between measuring
points
1: Move at clearance height between measuring
points
U
Preset value for rotation angle Q307 (absolute): If
the misalignment is to be measured against a straight
line other than the reference axis, enter the angle of
this reference line. The TNC will then calculate the
difference between the value measured and the
angle of the reference line for the basic rotation. Input
range -360.000 to 360.000
U
Preset number in table Q305: Enter the preset
number in the table in which the TNC is to save the
determined basic rotation. If you enter Q305=0, the
TNC automatically places the determined basic
rotation in the ROT menu of the Manual Operation
mode. Input range 0 to 2999
294
Example: NC blocks
5 TCH PROBE 400 BASIC ROTATION
Q263=+10 ;1ST POINT 1ST AXIS
Q264=+3.5 ;1ST POINT 2ND AXIS
Q265=+25 ;2ND POINT 1ST AXIS
Q266=+2
Q272=2
Q267=+1
Q261=-5
Q320=0
Q260=+20 ;CLEARANCE HEIGHT
Q301=0
Q307=0
Q305=0
Touch Probe Cycles: Automatic Measurement of Workpiece Misalignment
;2ND POINT 2ND AXIS
;MEASURING AXIS
;TRAVERSE DIRECTION
;MEASURING HEIGHT
;SET-UP CLEARANCE
;MOVE TO CLEARANCE
;PRESET ROTATION ANG.
;NO. IN TABLE