HEIDENHAIN TNC 320 User Manual page 361

Cycle programming
Hide thumbs Also See for TNC 320:
Table of Contents

Advertisement

2 TCH PROBE 413 DATUM OUTSIDE CIRCLE
Q321=+25 ;CENTER IN 1ST AXIS
Q322=+25 ;CENTER IN 2ND AXIS
Q262=30
;NOMINAL DIAMETER
Q325=+90 ;STARTING ANGLE
Q247=+45 ;STEPPING ANGLE
Q261=-5
;MEASURING HEIGHT
Q320=2
;SET-UP CLEARANCE
Q260=+10 ;CLEARANCE HEIGHT
Q301=0
;MOVE TO CLEARANCE
Q305=0
;NO. IN TABLE
Q331=+0
;DATUM
Q332=+10 ;DATUM
Q303=+0
;MEAS. VALUE TRANSFER
Q381=1
;PROBE IN TS AXIS
Q382=+25 ;1ST CO. FOR TS AXIS
Q383=+25 ;2ND CO. FOR TS AXIS
Q384=+25 ;3RD CO. FOR TS AXIS
Q333=+0
;DATUM
Q423=4
;NO. OF MEAS. POINTS
Q365=0
;TYPE OF TRAVERSE
3 CALL PGM 35K47
4 END PGM CYC413 MM
HEIDENHAIN TNC 320
Center of circle: X coordinate
Center of circle: Y coordinate
Circle diameter
Polar coordinate angle for 1st touch point
Stepping angle for calculating the starting points 2 to 4
Coordinate in the touch probe axis in which the measurement is
made
Safety clearance in addition to SET_UP column
Height in the touch probe axis at which the probe can traverse
without collision
Do not move to clearance height between measuring points
Set display
Set the display in X to 0
Set the display in Y to 10
Without function, since display is to be set
Also set datum in the touch probe axis
X coordinate of touch point
Y coordinate of touch point
Z coordinate of touch point
Set the display in Z to 0
Measure circle with 4 probes
Move on circular path between measuring points
Call part program
361