Trunk Promiscuous And Trunk Secondary Port Configuration Example - HP FlexFabric 12900 Series Configuration Manual

Layer 2-lan switching
Hide thumbs Also See for FlexFabric 12900 Series:
Table of Contents

Advertisement

Trunk promiscuous and trunk secondary port configuration
example
Network requirements
As shown in
VLANs 10 and 20 are primary VLANs on Device A. The uplink port Ten-GigabitEthernet 1/0/5 on
Device A permits the packets from VLANs 10 and 20 to pass through tagged.
VLAN 1 1, VLAN 12, VLAN 21, and VLAN 22 are secondary VLANs on Device A.
The downlink port Ten-GigabitEthernet 1/0/2 permits the packets from VLAN 1 1 and VLAN 21
to pass through tagged.
The downlink port Ten-GigabitEthernet 1/0/1 permits VLAN 22.
The downlink port Ten-GigabitEthernet 1/0/3 permits VLAN 12.
Secondary VLANs 1 1 and 12 are associated with primary VLAN 10.
Secondary VLANs 21 and 22 are associated with primary VLAN 20.
Figure 40 Network diagram
Configuration procedure
1.
Configure Device A:
# Configure VLANs 10 and 20 as primary VLANs.
<DeviceA> system-view
[DeviceA] vlan 10
[DeviceA-vlan10] private-vlan primary
[DeviceA-vlan10] quit
[DeviceA] vlan 20
[DeviceA-vlan20] private-vlan primary
[DeviceA-vlan20] quit
Figure
40, configure the private VLAN feature to meet the following requirements:
144

Advertisement

Table of Contents
loading